{"id":5908,"date":"2024-01-03T16:22:55","date_gmt":"2024-01-03T12:22:55","guid":{"rendered":"https:\/\/eiwaagroup.com\/?p=5908"},"modified":"2025-05-14T10:37:15","modified_gmt":"2025-05-14T06:37:15","slug":"how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation","status":"publish","type":"post","link":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/","title":{"rendered":"How to do Fuel oil Storage tank Calibration and Tank strapping?"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"5908\" class=\"elementor elementor-5908\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-13c2a99b elementor-section-boxed elementor-section-height-default elementor-section-height-default rt-parallax-bg-no\" data-id=\"13c2a99b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-151ca3a8\" data-id=\"151ca3a8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7ecff12c elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"7ecff12c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3 data-start=\"272\" data-end=\"288\"><strong data-start=\"276\" data-end=\"288\">Overview<\/strong><\/h3><p data-start=\"290\" data-end=\"641\"><strong data-start=\"290\" data-end=\"338\">Above Ground Storage Tank (AGST) Calibration<\/strong> is a precision process used to determine the exact volume of a storage tank for accurate measurement of stored products. Calibration is performed in accordance with the <strong data-start=\"508\" data-end=\"595\">API Manual of Petroleum Measurement Standards Chapter 2, Section 2D (API MPMS 2.2D)<\/strong>, using advanced 3D laser scanning technology.<\/p><p data-start=\"643\" data-end=\"927\">This method, also known as <strong data-start=\"670\" data-end=\"725\">EODR Calibration (Electro Optical Distance Ranging)<\/strong>, operates on the principles of <strong data-start=\"757\" data-end=\"796\">LiDAR (Light Detection and Ranging)<\/strong>. The process uses a high-precision total station or 3D laser scanner to collect x, y, z coordinates of the internal tank geometry.<\/p><hr data-start=\"929\" data-end=\"932\" \/><h3 data-start=\"934\" data-end=\"982\"><strong data-start=\"938\" data-end=\"982\">Principle of EODR (3D Laser Calibration)<\/strong><\/h3><p data-start=\"984\" data-end=\"1361\">EODR calibration technology uses a laser source that detects surfaces and objects within a <strong data-start=\"1075\" data-end=\"1089\">360-degree<\/strong> field and up to <strong data-start=\"1106\" data-end=\"1120\">120 meters<\/strong> in range. The scanner captures millions of data points, generating a 3D model of the tank interior, enabling accurate volume computations. This technique minimizes human error, enhances data reliability, and ensures repeatable measurements.<\/p><hr data-start=\"1363\" data-end=\"1366\" \/><h3 data-start=\"1368\" data-end=\"1411\"><strong data-start=\"1372\" data-end=\"1411\">Pre-Assessment for Tank Calibration<\/strong><\/h3><p data-start=\"1413\" data-end=\"1538\">Before initiating the calibration process, a <strong data-start=\"1458\" data-end=\"1476\">pre-assessment<\/strong> must be conducted by the Calibration Engineer to verify that:<\/p><ul data-start=\"1540\" data-end=\"1843\"><li data-start=\"1540\" data-end=\"1617\">All <strong data-start=\"1546\" data-end=\"1580\">major repairs or modifications<\/strong> to the tank structure are completed.<\/li><li data-start=\"1540\" data-end=\"1617\"><strong data-start=\"1620\" data-end=\"1653\">NDT (Non-Destructive Testing)<\/strong> and <strong data-start=\"1658\" data-end=\"1681\">Hydrostatic Testing<\/strong> have been performed in accordance with <strong data-start=\"1721\" data-end=\"1732\">API 650<\/strong> and <strong data-start=\"1737\" data-end=\"1748\">API 653<\/strong> standards.<\/li><li data-start=\"1540\" data-end=\"1617\">The tank interior is <strong data-start=\"1783\" data-end=\"1797\">clean, dry<\/strong>, and <strong data-start=\"1803\" data-end=\"1826\">free of scaffolding<\/strong> or obstructions.<\/li><\/ul><hr data-start=\"1845\" data-end=\"1848\" \/><h3 data-start=\"1850\" data-end=\"1893\"><strong data-start=\"1854\" data-end=\"1893\">Fuel Oil Tank Calibration Procedure<\/strong><\/h3><p data-start=\"1895\" data-end=\"2170\">Calibration (or <strong data-start=\"1911\" data-end=\"1924\">strapping<\/strong>) is the science of determining the <strong data-start=\"1960\" data-end=\"1975\">true volume<\/strong> of a tank at various fill levels. This data is used to develop a <strong data-start=\"2041\" data-end=\"2062\">calibration chart<\/strong> or <strong data-start=\"2066\" data-end=\"2082\">volume table<\/strong>, which is critical for inventory control, custody transfer, and product reconciliation.<\/p><hr data-start=\"2172\" data-end=\"2175\" \/><h3 data-start=\"2177\" data-end=\"2222\"><strong data-start=\"2181\" data-end=\"2222\">Key Terminologies in Tank Calibration<\/strong><\/h3><div class=\"_tableContainer_16hzy_1\"><div class=\"_tableWrapper_16hzy_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\"><table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2224\" data-end=\"3184\"><thead data-start=\"2224\" data-end=\"2253\"><tr data-start=\"2224\" data-end=\"2253\"><th data-start=\"2224\" data-end=\"2235\" data-col-size=\"sm\"><strong data-start=\"2226\" data-end=\"2234\">Term<\/strong><\/th><th data-start=\"2235\" data-end=\"2253\" data-col-size=\"lg\"><strong data-start=\"2237\" data-end=\"2251\">Definition<\/strong><\/th><\/tr><\/thead><tbody data-start=\"2284\" data-end=\"3184\"><tr data-start=\"2284\" data-end=\"2435\"><td data-start=\"2284\" data-end=\"2302\" data-col-size=\"sm\"><strong data-start=\"2286\" data-end=\"2301\">Datum Plate<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2302\" data-end=\"2435\">The plate located at the base of the tank on the vertical axis beneath the dipping reference point. Used as a measurement origin.<\/td><\/tr><tr data-start=\"2436\" data-end=\"2519\"><td data-start=\"2436\" data-end=\"2452\" data-col-size=\"sm\"><strong data-start=\"2438\" data-end=\"2451\">Dip Hatch<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2452\" data-end=\"2519\">An opening on the tank roof for sampling, dipping, or ullaging.<\/td><\/tr><tr data-start=\"2520\" data-end=\"2640\"><td data-start=\"2520\" data-end=\"2535\" data-col-size=\"sm\"><strong data-start=\"2522\" data-end=\"2534\">Dip Pipe<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2535\" data-end=\"2640\">A guide pipe installed from the dip hatch down to the datum plate, essential for floating roof tanks.<\/td><\/tr><tr data-start=\"2641\" data-end=\"2770\"><td data-start=\"2641\" data-end=\"2669\" data-col-size=\"sm\"><strong data-start=\"2643\" data-end=\"2668\">Shell Plate Thickness<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2669\" data-end=\"2770\">Thickness (in mm) of each tank shell course, measured via Ultrasonic Thickness Measurement (UTM).<\/td><\/tr><tr data-start=\"2771\" data-end=\"2867\"><td data-start=\"2771\" data-end=\"2789\" data-col-size=\"sm\"><strong data-start=\"2773\" data-end=\"2788\">Tank Height<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2789\" data-end=\"2867\">Vertical distance between the dipping reference point and the datum plate.<\/td><\/tr><tr data-start=\"2868\" data-end=\"2961\"><td data-start=\"2868\" data-end=\"2878\" data-col-size=\"sm\"><strong data-start=\"2870\" data-end=\"2877\">Dip<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2878\" data-end=\"2961\">The distance from the datum plate to the product surface level inside the tank.<\/td><\/tr><tr data-start=\"2962\" data-end=\"3052\"><td data-start=\"2962\" data-end=\"2975\" data-col-size=\"sm\"><strong data-start=\"2964\" data-end=\"2974\">Course<\/strong><\/td><td data-col-size=\"lg\" data-start=\"2975\" data-end=\"3052\">A horizontal circumferential ring of steel plates forming the tank shell.<\/td><\/tr><tr data-start=\"3053\" data-end=\"3184\"><td data-start=\"3053\" data-end=\"3068\" data-col-size=\"sm\"><strong data-start=\"3055\" data-end=\"3067\">Deadwood<\/strong><\/td><td data-col-size=\"lg\" data-start=\"3068\" data-end=\"3184\">Internal components that affect tank volume. <em data-start=\"3115\" data-end=\"3134\">Positive deadwood<\/em> adds to volume; <em data-start=\"3151\" data-end=\"3170\">Negative deadwood<\/em> reduces it.<\/td><\/tr><\/tbody><\/table><div class=\"sticky end-(--thread-content-margin) h-0 self-end select-none\"><div class=\"absolute end-0 flex items-end\">\u00a0<\/div><\/div><\/div><\/div><hr data-start=\"3186\" data-end=\"3189\" \/><h3 data-start=\"3191\" data-end=\"3225\"><strong data-start=\"3195\" data-end=\"3225\">EODR Calibration Procedure<\/strong><\/h3><ol data-start=\"3227\" data-end=\"3655\"><li data-start=\"3227\" data-end=\"3289\"><p data-start=\"3230\" data-end=\"3289\"><strong data-start=\"3230\" data-end=\"3239\">Setup<\/strong> \u2013 The 3D laser scanner is placed inside the tank.<\/p><\/li><li data-start=\"3290\" data-end=\"3391\"><p data-start=\"3293\" data-end=\"3391\"><strong data-start=\"3293\" data-end=\"3305\">Scanning<\/strong> \u2013 The scanner rotates and collects millions of data points from the internal surface.<\/p><\/li><li data-start=\"3392\" data-end=\"3510\"><p data-start=\"3395\" data-end=\"3510\"><strong data-start=\"3395\" data-end=\"3414\">Data Processing<\/strong> \u2013 Specialized software generates a 3D point cloud and computes the actual geometry of the tank.<\/p><\/li><li data-start=\"3511\" data-end=\"3655\"><p data-start=\"3514\" data-end=\"3655\"><strong data-start=\"3514\" data-end=\"3536\">Volume Calculation<\/strong> \u2013 From this 3D model, a detailed volume table is created, showing precise tank capacities at incremental fill heights.<\/p><\/li><\/ol><hr data-start=\"3657\" data-end=\"3660\" \/><h3 data-start=\"3662\" data-end=\"3710\"><strong data-start=\"3666\" data-end=\"3710\">Storage Tank Calibration Chart Includes:<\/strong><\/h3><ul data-start=\"3712\" data-end=\"4095\"><li data-start=\"3712\" data-end=\"3750\">Shell <strong data-start=\"3720\" data-end=\"3750\">plate thickness per course<\/strong><\/li><li data-start=\"3751\" data-end=\"3774\">Total <strong data-start=\"3759\" data-end=\"3774\">tank height<\/strong><\/li><li data-start=\"3751\" data-end=\"3774\"><strong data-start=\"3777\" data-end=\"3800\">Safe filling height<\/strong><\/li><li data-start=\"3801\" data-end=\"3841\"><strong data-start=\"3803\" data-end=\"3815\">Tiltness<\/strong> or out-of-plumb deviation<\/li><li data-start=\"3801\" data-end=\"3841\"><strong data-start=\"3844\" data-end=\"3857\">Elevation<\/strong> or vertical position of tank<\/li><li data-start=\"3801\" data-end=\"3841\">Dimensions of internal <strong data-start=\"3912\" data-end=\"3929\">appurtenances<\/strong> (nozzles, manholes, heating coils, etc.)<\/li><li data-start=\"3801\" data-end=\"3841\"><strong data-start=\"3973\" data-end=\"3990\">Floating roof<\/strong> height and design specifics<\/li><li data-start=\"3801\" data-end=\"3841\"><strong data-start=\"4021\" data-end=\"4036\">Temperature<\/strong> and <strong data-start=\"4041\" data-end=\"4052\">density<\/strong> of product (for volume correction factors)<\/li><\/ul><hr data-start=\"4097\" data-end=\"4100\" \/><h3 data-start=\"4102\" data-end=\"4138\"><strong data-start=\"4106\" data-end=\"4138\">Benefits of EODR Calibration<\/strong><\/h3><ul data-start=\"4140\" data-end=\"4363\"><li data-start=\"4140\" data-end=\"4184\"><strong data-start=\"4142\" data-end=\"4159\">Non-intrusive<\/strong> and fast data collection<\/li><li data-start=\"4185\" data-end=\"4217\"><strong data-start=\"4187\" data-end=\"4204\">High-accuracy<\/strong> measurements<\/li><li data-start=\"4218\" data-end=\"4265\">No need for manual strapping or emptying tank<\/li><li data-start=\"4266\" data-end=\"4306\">Enhanced <strong data-start=\"4277\" data-end=\"4287\">safety<\/strong> and <strong data-start=\"4292\" data-end=\"4306\">efficiency<\/strong><\/li><li data-start=\"4307\" data-end=\"4363\">Conforms with <strong data-start=\"4323\" data-end=\"4330\">API<\/strong>, <strong data-start=\"4332\" data-end=\"4339\">ISO<\/strong>, and industry standards<\/li><\/ul><hr data-start=\"4365\" data-end=\"4368\" \/><h3 data-start=\"4370\" data-end=\"4388\"><strong data-start=\"4374\" data-end=\"4388\">Conclusion<\/strong><\/h3><p data-start=\"4390\" data-end=\"4687\">Modern above ground storage tank calibration using <strong data-start=\"4441\" data-end=\"4472\">LiDAR-based EODR technology<\/strong> provides unmatched accuracy and reliability. By leveraging 3D scanning, facilities can optimize inventory control, ensure compliance with international standards, and reduce operational downtime during measurement.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Overview Above Ground Storage Tank (AGST) Calibration is a precision process used to determine the exact volume of a storage tank for accurate measurement of stored products. Calibration is performed in accordance with the API Manual of Petroleum Measurement Standards Chapter 2, Section 2D (API MPMS 2.2D), using advanced 3D laser scanning technology. This method, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[1],"tags":[],"class_list":["post-5908","post","type-post","status-publish","format-standard","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Oil Tank Strapping and Fuel Oil Tank Calibration Procedure<\/title>\n<meta name=\"description\" content=\"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration &amp; EODR by API 650.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Oil Tank Strapping and Fuel Oil Tank Calibration Procedure\" \/>\n<meta property=\"og:description\" content=\"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration &amp; EODR by API 650.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/\" \/>\n<meta property=\"og:site_name\" content=\"Eiwaa Group\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/eiwaamarine\" \/>\n<meta property=\"article:published_time\" content=\"2024-01-03T12:22:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-14T06:37:15+00:00\" \/>\n<meta name=\"author\" content=\"Admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@eiwaamarine\" \/>\n<meta name=\"twitter:site\" content=\"@eiwaamarine\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/\"},\"author\":{\"name\":\"Admin\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#\\\/schema\\\/person\\\/1fb56dd8fcd9dfc72291213362e96a9d\"},\"headline\":\"How to do Fuel oil Storage tank Calibration and Tank strapping?\",\"datePublished\":\"2024-01-03T12:22:55+00:00\",\"dateModified\":\"2025-05-14T06:37:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/\"},\"wordCount\":589,\"publisher\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#organization\"},\"inLanguage\":\"en\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/\",\"url\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/\",\"name\":\"Oil Tank Strapping and Fuel Oil Tank Calibration Procedure\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#website\"},\"datePublished\":\"2024-01-03T12:22:55+00:00\",\"dateModified\":\"2025-05-14T06:37:15+00:00\",\"description\":\"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration & EODR by API 650.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/#breadcrumb\"},\"inLanguage\":\"en\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to do Fuel oil Storage tank Calibration and Tank strapping?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#website\",\"url\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/\",\"name\":\"www.eiwaagroup.com\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#organization\",\"name\":\"EIWAA MARINE SERVICE LLC\",\"url\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Eiwaa-Logo.png\",\"contentUrl\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/wp-content\\\/uploads\\\/2023\\\/11\\\/Eiwaa-Logo.png\",\"width\":150,\"height\":102,\"caption\":\"EIWAA MARINE SERVICE LLC\"},\"image\":{\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/eiwaamarine\",\"https:\\\/\\\/x.com\\\/eiwaamarine\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/eiwaa-marine-services-fujairah-abudhabi-saudiarabia\\\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/#\\\/schema\\\/person\\\/1fb56dd8fcd9dfc72291213362e96a9d\",\"name\":\"Admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g\",\"caption\":\"Admin\"},\"sameAs\":[\"https:\\\/\\\/eiwaagroup.com\\\/angola\"],\"url\":\"https:\\\/\\\/eiwaagroup.com\\\/angola\\\/author\\\/eiwaa_admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Oil Tank Strapping and Fuel Oil Tank Calibration Procedure","description":"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration & EODR by API 650.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/","og_locale":"en_US","og_type":"article","og_title":"Oil Tank Strapping and Fuel Oil Tank Calibration Procedure","og_description":"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration & EODR by API 650.","og_url":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/","og_site_name":"Eiwaa Group","article_publisher":"https:\/\/www.facebook.com\/eiwaamarine","article_published_time":"2024-01-03T12:22:55+00:00","article_modified_time":"2025-05-14T06:37:15+00:00","author":"Admin","twitter_card":"summary_large_image","twitter_creator":"@eiwaamarine","twitter_site":"@eiwaamarine","twitter_misc":{"Written by":"Admin","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/#article","isPartOf":{"@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/"},"author":{"name":"Admin","@id":"https:\/\/eiwaagroup.com\/angola\/#\/schema\/person\/1fb56dd8fcd9dfc72291213362e96a9d"},"headline":"How to do Fuel oil Storage tank Calibration and Tank strapping?","datePublished":"2024-01-03T12:22:55+00:00","dateModified":"2025-05-14T06:37:15+00:00","mainEntityOfPage":{"@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/"},"wordCount":589,"publisher":{"@id":"https:\/\/eiwaagroup.com\/angola\/#organization"},"inLanguage":"en"},{"@type":"WebPage","@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/","url":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/","name":"Oil Tank Strapping and Fuel Oil Tank Calibration Procedure","isPartOf":{"@id":"https:\/\/eiwaagroup.com\/angola\/#website"},"datePublished":"2024-01-03T12:22:55+00:00","dateModified":"2025-05-14T06:37:15+00:00","description":"Procedure for Storage Tank Calibration, Storage Tank Strapping ,Safe Fill Height Measurement and Dipstick supply by 3D Laser Calibration & EODR by API 650.","breadcrumb":{"@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/#breadcrumb"},"inLanguage":"en","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/eiwaagroup.com\/angola\/how-to-do-fuel-oil-storage-tank-calibration-tank-strapping-and-dipstick-preparation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/eiwaagroup.com\/angola\/"},{"@type":"ListItem","position":2,"name":"How to do Fuel oil Storage tank Calibration and Tank strapping?"}]},{"@type":"WebSite","@id":"https:\/\/eiwaagroup.com\/angola\/#website","url":"https:\/\/eiwaagroup.com\/angola\/","name":"www.eiwaagroup.com","description":"","publisher":{"@id":"https:\/\/eiwaagroup.com\/angola\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/eiwaagroup.com\/angola\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en"},{"@type":"Organization","@id":"https:\/\/eiwaagroup.com\/angola\/#organization","name":"EIWAA MARINE SERVICE LLC","url":"https:\/\/eiwaagroup.com\/angola\/","logo":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/eiwaagroup.com\/angola\/#\/schema\/logo\/image\/","url":"https:\/\/eiwaagroup.com\/angola\/wp-content\/uploads\/2023\/11\/Eiwaa-Logo.png","contentUrl":"https:\/\/eiwaagroup.com\/angola\/wp-content\/uploads\/2023\/11\/Eiwaa-Logo.png","width":150,"height":102,"caption":"EIWAA MARINE SERVICE LLC"},"image":{"@id":"https:\/\/eiwaagroup.com\/angola\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/eiwaamarine","https:\/\/x.com\/eiwaamarine","https:\/\/www.linkedin.com\/company\/eiwaa-marine-services-fujairah-abudhabi-saudiarabia\/"]},{"@type":"Person","@id":"https:\/\/eiwaagroup.com\/angola\/#\/schema\/person\/1fb56dd8fcd9dfc72291213362e96a9d","name":"Admin","image":{"@type":"ImageObject","inLanguage":"en","@id":"https:\/\/secure.gravatar.com\/avatar\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/7fa0a6d58dbc9463dd3de3efe16a53f78a2b8f9977a0d7349bbe42ab8aa41e7f?s=96&d=mm&r=g","caption":"Admin"},"sameAs":["https:\/\/eiwaagroup.com\/angola"],"url":"https:\/\/eiwaagroup.com\/angola\/author\/eiwaa_admin\/"}]}},"_links":{"self":[{"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/posts\/5908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/comments?post=5908"}],"version-history":[{"count":16,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/posts\/5908\/revisions"}],"predecessor-version":[{"id":8436,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/posts\/5908\/revisions\/8436"}],"wp:attachment":[{"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/media?parent=5908"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/categories?post=5908"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/eiwaagroup.com\/angola\/wp-json\/wp\/v2\/tags?post=5908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}